・Chamfer the tap.(CO.2-CO.5)
・The full length of the pilot hole should fully take the active length of the insert.
・Tap can be purchased by marketing. (It is not a tap only for an insert.)
Insert specifications | Pilot hole drilling | ||||
---|---|---|---|---|---|
Insert nominal diameter | Female thread×pitch | Outer diameter | Pilot hole | Tolerance | Tap |
M2 | M2×P0.4 | M3×P0.5 | Φ2.5 | ±0.04 | M3×P0.5 |
M2.5 | M2.5×P0.45 | M4×P0.5 | Φ3.5 | ±0.04 | M4×P0.5 |
M2.6 | M2.6×P0.45 | M4×P0.5 | Φ3.5 | ±0.04 | M4×P0.5 |
M3 | M3×P0.5 | M4×P0.5 | Φ3.5 | ±0.04 | M4×P0.5 |
M4 | M4×P0.7 | M5×P0.5 | Φ4.5 | ±0.04 | M5×P0.5 |
M5 | M5×P0.8 | M6×P0.5 | Φ5.5 | ±0.04 | M6×P0.5 |
M6 | M6×P1.0 | M8×P0.75 | Φ7.3 | ±0.04 | M8×P0.75 |
M8 | M8×P1.25 | M10×P10 | Φ9.0 | ±0.04 | M10×P1.0 |
LOCTITE 516 is a water-based preapplied thread sealant that is high-viscosity, non-toxic, and thixotropic.
Note: Not suitable for long-term storage under high humidity conditions due to water-solubility.